✓
**Transformer & Switchgear CRGO Core, Winding & IEC 60076 Command Center (OWL 2)**: Real-time shopfloor telemetry displaying Total Transformer & Switchgear Jobs, Total Rated Capacity (kVA), CRGO Silicon Steel Core Weight (kg), HV/LV Copper & Aluminum Conductor Gross vs Offcut Scrap (kg), IEC 60076 Certified Routine Test Pass Rate, and Net Manufacturing Cost after Copper Scrap Credits.
✓
**Transformer & Switchgear Manufacturing Job (`transformer.manufacturing.job`)**: Track complete electrical equipment jobs (`TRF/2026/0001`) across equipment types (`11/0.415kV Oil-Immersed Distribution Transformer`, `33/11kV ONAN/ONAF Power Transformer`, `Dry-Type Cast Resin Transformer (CRT)`, `11kV/33kV HT VCB Indoor/Outdoor Switchgear`, `Package Compact Substation (CSS)`), kVA rating, vector group & cooling (`Dyn11 · ONAN / ONAF · 50Hz`), CRGO core grade & weight (kg), HV/LV conductor type, gross conductor (kg), offcut scrap (kg), insulating oil liters, VPD vacuum drying mbar, CRGO core cost, winding conductor cost, tank/oil/bushing cost, copper scrap credit, and computed `net_manufacturing_cost`.
✓
**HV/LV Coil Winding, CRGO Core Stacking & Busbar Log (`transformer.winding.core.log`)**: Record shopfloor coil winding and core assembly operations (`WND/2026/0001`) including coil section (`LV Foil / Rectangular Strip Winding`, `HV Disc / Crossover Coil Winding`, `Step-Lap CRGO Core Slitting & Stacking`, `HT/LT Busbar Riser & Lead Brazing`), designed vs actual wound turns, micro-ohmmeter DC resistance (Ω), axial hydraulic clamping pressure (kN), and post-VPD oil moisture (ppm).
✓
**IEC 60076 / IS 2026 Routine & Type Test Bay Log (`transformer.iec.routine.test`)**: Log high-voltage test bay certifications (`TRT/2026/0001`) including guaranteed vs measured no-load iron loss (W), guaranteed vs measured load copper loss at 75°C (W), % impedance voltage (%Z), Megger insulation resistance (GΩ), dielectric oil BDV (kV), lightning impulse BIL withstand (kVp), and IEC 60076 verdict (`IEC 60076 Certified Pass (Zero Penalty)`, `Pass Within IEC +10% Loss Tolerance`, `Hold — Core/Winding Retest Required`).
✓
**2 Printable QWeb PDF Reports**: 1. *Transformer & Switchgear CRGO Core, HV/LV Winding, VPD Drying & Net Cost Dossier PDF* 2. *IEC 60076 / IS 2026 Routine & Type Test Certificate (Iron/Copper Loss, Impedance % & Oil BDV kV) PDF*
✓
How do I automate and manage Transformer & Switchgear Manufacturing, CRGO Core in Odoo 18 Community & Enterprise? Manage distribution & power transformer jobs, CRGO core step-lap stacking, HV/LV copper/aluminum coil winding, VPD drying, scrap credit & IEC 60076 routine testing. Key workflows include: Transformer & Switchgear CRGO Core, Winding & IEC 60076 Command Center (OWL 2) (Real-time shopfloor telemetry displaying Total Transformer & Switchgear Jobs, Total Rated Capac); Transformer & Switchgear Manufacturing Job (Track complete electrical equipment jobs (TRF/2026/0001) across equipment types (11/0.415kV Oil); HV/LV Coil Winding, CRGO Core Stacking & Busbar Log (Record shopfloor coil winding and core assembly operations (WND/2026/0001) including coil secti).
✓
Does Transformer & Switchgear Manufacturing, CRGO Core work on Odoo 18 Community Edition as well as Enterprise? Yes. It is 100% compatible with both Odoo 18.0 Community and Enterprise (On-Premise, Cloud, and Odoo.sh), depending only on standard open-source Odoo modules (base, mail, product, uom) with no extra paid Enterprise dependencies.